CODESYS PROFINET Controller SL

Mit dem Produkt CODESYS PROFINET Controller SL können Endanwender ein PROFINET-Netzwerk mit einer CODESYS-kompatiblen Steuerung realisieren.

Artikelnummer
2303000015
150,00 €
Zzgl. Mehrwertsteuer
License Agreement

 

for the usage of a CODESYS Software or CODESYS Software Package

 

General Terms of License (End User License Agreement) for the supplied Software. Please read this Software User Agreement carefully before using the supplied Software. Downloading or installation of the Software constitutes recognition by the customer of the conditions of this Agreement.

The following conditions are agreed between you as the software user and the company 3S-Smart Software Solutions GmbH (hereinafter referred to as 3S), 87439 Kempten (Germany) and are legally binding.

With this license agreement, you acquire the permission of use for Software from 3S (e. g. http://codesys.com, http://store.codesys.com). Some products may only be used for a limited period of time (Products with the name affix “Abo”, “Abonnement” or “Subscription”). If you do not agree to the following license agreement, then you, the user, are not permitted to save and/or install the Software. Should you have already installed the Software, and you do not agree to the license agreement, then immediately delete or uninstall the Software.

§ 1       Object of the License Agreement

The object of the License Agreement is the supplied Software that you have received either directly or from the CODESYS Store. With the provided Software, the user is in the position to use and/or to extend the CODESYS Development System and/or implement a CODESYS runtime environment on a specific programmable logic controller (PLC), herein termed "device". The user has the right to install the functions of the Software after installation of the device software and/or the CODESYS Development System.

In this way, the user can use the functions as specified in the data sheet of the Software.

§ 2       Geographic Restriction

None

§ 3       Rights of Use

Different license models grant different usage rights. A CODESYS Softcontainer or CODESYS Key (hardware dongle) is required to use the demo, full or time license.

Free: Software that is indicated as "Free" in the CODESYS Store is not subject to an automatic license check by the manufacturer and can be used free of charge.

Demo: The user can order a simple and non-transferable demo license to the supplied Software, depending on availability. The license protected demo software is free of charge but limited by time and/or functionality.

Full: The provided Software is protected by license and requires a fee. The user acquires an unrestricted, simple, and non-transferable license to use the supplied Software with no restrictions.

Time license: Alternatively, a time-limited license is offered to the user, with which the user acquires a simple, non-transferable license to use the delivered software for an agreed, contiguous period.

It is not permitted to edit, modify, disassemble or decompile the Software or to use other processes of reverse engineering to by-pass the licensing mechanism, or to have these processes performed by third parties, insofar as this is not absolutely required for exploiting the rights that result from licenses in all events for open source components.

The Software can be components that are licensed as open source software. For these components, the contents of the respective open source licenses apply, as also stored in the Software. The list of components with the terms and conditions of license are available for reading before purchase and are also included in the Software. The licensee receives a simple rights of use from the respective right holders for using the open source software under the conditions as provided for it by the respective valid license terms. The provided license terms apply to only the components that are not licensed as open source software.

All rights regarding the usage and exploitation of the software and Software remain reserved to 3S.

§ 4       Warranty

4.1.    The manufacturer warrants that the installed Software will substantially conform to its documentation or data sheet. The following restrictions shall apply. In particular, there is no warranty that the Software fulfills the specific requirements of the user, serves his specific purpose and works together with all the other programs selected by the user, in so far as interfaces to these programs have not been agreed upon in writing.

4.2.    It is deemed to be agreed and the user recognizes and accepts that, according to the current state of knowledge and technology, it is not possible to create software in such a way that it works without errors or faults under all application conditions. A deviation from the agreed properties of the Software can only be considered significant if normal operation is substantially disrupted. If a disruption occurs under exceptional circumstances, this cannot be considered as a deviation from the agreed properties of the Software. 

4.3.    The user shall immediately examine the Software supplied, shall establish its appropriateness for the intended purpose and shall immediately issue complaints about initial or non-initial errors/defects in detail and in such a way that the error/defect can be reproduced by the manufacturer. The user agrees to provide 3S with material giving information on the nature and occurrence of these errors/defects in order to contribute to their localization and correction. The user bears sole responsibility for the selection, installation and use of the Software, as well as for the intended results thereof.

4.4.    The manufacturer does not provide a warranty for errors or defects that are caused by or result from the following circumstances:

(a)     Incorrect or insufficient maintenance or parameterization

(b)     Operation outside the software’s specification

(c)     Incorrect preparation and/or maintenance of the installation location

(d)     Interaction with hardware or software not released by the manufacturer

A special guarantee which could result in additional rights is not provided.

4.5.    Any defects with regard to the supplied Software (including defects with regard to the program description and any other documents provided along with the Software), will be rectified by the manufacturer within an appropriate period of time. The manufacturer has the right to decide between rework/repair free of charge or replacement at its own discretion.

4.6     The conditions for liability and warranty in these license terms are valid for the complete Software with respect to the manufacturer. The liability and warranty conditions of the open source licenses are valid between the user and the open source right holders.

§ 5       Limitation of Liability

The Software can be used for numerous applications. The user shall decide independently whether or not it is also appropriate for the actual intended application. After installation, the user is responsible for the Software functioning according to its specifications.

The manufacturer is liable for intentional acts and gross negligence. The manufacturer shall be liable for slight negligence only if this involves the breach of a major obligation deemed essential for the purpose of the contract (cardinal obligation) and the fulfillment of which the customer may regularly rely upon or for damages resulting from injury to life body or health. The manufacturer is obliged to act with due diligence.

Upon the determination of whether the manufacturer has culpability, it is to be considered that, as a matter of fact, it is not possible to provide software on an error-free basis. For events of slight negligence, total liability is limited to the amount of the foreseeable damage, the occurrence of which must typically be expected; however, the maximum of such liability arising from the contractual relationship is limited to a total of EURO 100,000.00. The manufacturer shall not be liable for other damages, consequential damages, or lost profits.

The preceding provisions also apply in favour of any vicarious agent of the manufacturer. Liability under product liability law remains unaffected. For the loss of data and/or programs, the manufacturer is not liable insofar the damages are based on the fact that the user refrained from conducting data security measures and thereby ensuring that the lost data could be restored with a justifiable expense. Before commissioning the device and an application written with the CODESYS Development System, the user is obligated to perform sufficient tests in a safe environment.

§ 6       Termination

For non-time limited software this Agreement may be terminated at any time by uninstalling from the device the described Software from the manufacturer and destroying all copies thereof.

If the software is limited in time (subscription or subscription), the user agreement ends with the termination of the subscription or subscription on the expiry date of the agreed period of use. The termination of the time limited use can take place at any time, but must take place at the latest one month before the end of the expiration of the temporal limitation, in order to still be effective at the end of the current subscription period. If this does not take place or is done too late, the period of use is automatically extended by the period of the time limit agreed in the data sheet. After the end of the period of use, the functions of the software are no longer available or are only available to a very limited extent.

§ 7       Governing Law

This License Agreement shall be governed by the laws of the Federal Republic of Germany excluding CISG. The place of performance and the court of jurisdiction for all disputes arising from or in connection with this agreement is 87439 Kempten (Germany). Claims may also be asserted against each contracting party in its general place of jurisdiction.

 

 

§ 8       Severability Clause

Should one provision of this contract be or become invalid, or should the contract contain a gap, the validity of the remaining provisions shall remain unaffected. In place of the ineffective provisions, or in order to fill the gap, a provision shall apply which, in so far as legally viable, approaches the original intention of the contractual parties as closely as possible, or what can be assumed to have been their intention if they had considered the point in question.

Produktbeschreibung

PROFINET (Process Field Network) ist ein offener Standard für ein industrielles Echtzeit-Ethernet-System in der Automatisierung. Er wird von der Nutzerorganisation PI (PROFIBUS&PROFINET International als Dachorganisation der PROFIBUS-Nutzerorganisation PNO) geführt und gilt als Nachfolger von PROFIBUS. PROFINET nutzt das IEEE 802.3 (Standard Ethernet) basierte Profinet RT Protokoll für zyklische Echtzeit I/O Kommunikation und UDP/IP für azyklische Dienste.

Die vollständig integrierte CODESYS PROFINET Lösung bietet einen einheitlichen Konfigurator für die verschiedenen Varianten des PROFINET Controller Kommunikations-Stacks:

  • CODESYS PROFINET Controller (IEC)
    Protokoll Stack in Form einer CODESYS Bibliotheken (in IEC 61131-3 Code) arbeitet auf Standard Netzwerkinterfaces.
    Für CODESYS Control RTE sind spezielle Ethernet Treiber für sehr hohe Übertragungsleistung verfügbar (siehe Vorraussetzungen).
    Das Netzwerkinterface wird nicht exklusiv verwendet, es steht weiterhin für andere TCP/IP Anwendungen zur Verfügung (z.B. CODESYS Visualisation, Web Browser).

CODESYS PROFINET Konfigurator

  • Konfigurator für Einstellungen des PROFINET Controller

  • Konfiguration von Slaves(einzelne AR zum PROFINET Feldgerät) mit Kommunikationseinstellungen

  • Konfiguration von gerätespezifischen Einstellungen, Input- und Output - Mapping

  • Status Seite mit detailierter Ansicht der aktuell anliegenden Diagnose und der empfangenen Alarme

  • Scan Dialog mit Geräte-Import Funktion, Online/Offline Vergleich, I&M Daten

  • Topology Konfigurator (für Gerätetausch, IRT-Planung)

  • Media Redundancy (MRP) Konfigurator

Bild 1: Konfiguration mit Validierung

Bild 2: Diagnose in der Status Seite

Bild 3: Scan Dialog mit I&M Funktionen

Profinet-Stack (IEC)

Der CODESYS PROFINET Controller Stack kann im Prinzip auf jeder Standard Ethernet Hardware laufen (siehe Vorraussetzungen and Einschränkungen). Dieser Ethernet Adapter kann weiterhin für andere Dienste wie CODESYS Kommunikation (mit der IDE), Web-Server, oder anderen CODESYS Feldbussen (außer EtherCAT) verwendet werden. Das CODESYS Runtime und das Betriebsystem (z.B. Firewall) müssen richtig konfiguriert werden. Details dazu siehe CODESYS Online Help / Fieldbus Support (https://help.codesys.com/)

Feature

CODESYS PROFINET Controller (IEC)

PROFINET Specification

V2.42

Conformance Class

B

Max. Anzahl an Verbindungen

64 (default) - 1024

Max. IO-Daten (gesamt)

kein Limit

Max. IO-Daten (per slave)

1440 input und 1440 byte output

Max. acyclic Daten

16 KB

Plattformen / OS (siehe restrictions)

Windows, Linux, VxWorks, WinCE

CPU

32/64 Bit
Little-/Big-Endian

Provider-/Consumer-Status

ja

Automatic Name Assignment (Gerätetausch)

ja

Topologie-Konfiguration

ja

Fast Startup

ja

MRP-Konfiguration

ja

MRP-Rolle

Client, siehe Dual Port

Dual Port

ja, siehe unten

Shared Device

ja

Device Access AR

ja

System Redundancy

S2

Leistung

hängt vom System ab ( ** siehe unten)
getestet mit 64 Frames / ms
CODESYS CONTROLLER Device (IEC) und Dual-Port Interface:
Mit Standard Ethernet Adapter Hardware sind nur Single Port Devices möglich, d.h. jeder PROFINET Controller kann nur einen Port verwalten. (Das System selber kann mehr als einen Ethernet Adapter haben, darauf könnte z.B. noch ein PROFINET Device laufen).
Ein Dual-Port Device (z.B. für MRP oder eine sog.‘Daisy-Chain‘) kann mit speziellen Dual-Port (Bridge) Ethernet Chipsätzen umgesetzt werden, dies erfordert aber Anpassungen des Laufzeitsystems durch den OEM.

Performanz CODESYS PROFINET Controller (IEC):
Die IO Leistung, d.h. die möglichen übertragenen Ethernet Frames / ms ist, je nach Plattform, sehr unterschiedlich und reicht von hervorragend (CODESYS Control RTE) bis eher schwach (‚out of the box‘ Win CE).
Sie hängt nahezu ausschließlich von der SysEthernet - Implementierung des CODESYS Runtime ab.
Natürlich kann auch ein System, das nur 8 Frames / ms leistet, zum Beispiel 32 Feldgeräte ansteuern - aber eben ‚nur‘ bei einem Intervall von 4 ms.

Beispiel mit 1 ms Aktualisierungsrate:

Plattform

Frames / ms

CODESYS Control RTE

64

CODESYS Raspberry Pi SL

8

Programmier Interface (API für die IEC Applikation)

Der PROFINET Controller bietet eine umfangreiche API für Profinet Dienste und Hilfsfunktionen die zur Laufzeit von der Anwendung genutzt werden können.

Funktion

Beschreibung

DCP-Identify (Bus-Scan)

Function Block ProfinetCommon.DCP_Identify

DCP-Set/Get

Function Block ProfinetCommon.DCP_Set / DCP_Get
IP-Address oder Stationsname setzen / lesen

Factory Reset

Function Block ProfinetCommon.DCP_Reset

IO-Link

- Lesen / Schreiben von IO-Link Parametern mit Function Block ProfinetCommon.IOL_CALL
- Smart Sensor Profile Unterstützung mit Function Blocks in ProfinetCommon Bibliothek

Status Outputs

Impliziter Profinet Slave Function Block:
xRunning: Verbindung aufgebaut, Datenaustausch
xError: Verbindung abgebrochen / fehlgeschlagen
xDiagnosis: Diagnose steht an
xModuleDiff: Module Konfiguration abweichend (Modul falsch oder fehlt).

Status Outputs Controller

Impliziter Profinet Controller Function Block:
xOnline: Controller am Netz
xBusy: Controller im Hochlauf
xError: Fehler steht an
xDataValid: Alle IO-Daten der projektierten Geräte sind gültig

Dynamischer Verbindungsaufbau / -Abbruch

Impliziter Profinet Controller oder Slave Function Block, Methode SetCommunicationState()

Generischer Zugriff auf Geräte oder Module Konfiguration

Function Block ProfinetCommon.DeviceIterator und SubmoduleIterator
Generische API zum Iterieren von Slave- oder Modul-Konfiguration sowie Zugriff auf Modul-Status

Diagnosis Shadowing

Function Block ProfinetCommon.DiagnosisBuffer
Diagnose Daten werden lokal gepuffert

Alarme empfangen

Function Block CommFB.RALARM

Azyklisches Lesen/Schreiben

Function Block CommFB.RDREC / WRREC

Direkter Zugriff auf IO-Daten

Function Block CommFB.SETIO_PART / GETIO_PART

Device-Access AR

Function Block CommFB.CNCT

Reconfigure

Function Block DED.Reconfigure:
Module, Slaves oder den gesamten Profinet Stack aktivieren / deaktivieren
Function Block IoDrvProfinetBase.ControllerConfigUtil:
Ändern von konfiguriertem Stationsnamen, Slot / Subslot oder Geräte-Einstellungen zur Laufzeit.

Requirements

Programmiersystem

CODESYS Development System V3.5.17.0 oder höher

Laufzeitsystem

CODESYS Control Version 3.5.17.0 oder höher

Unterstützte Plattformen/ Geräte

CODESYS Laufzeitsystem mit diesen Komponenten
* SysEthernet
* SysSocket

Hinweis: Verwenden Sie das Projekt Device Reader, um die von der Steuerung unterstützten Funktionen zu ermitteln. Device Reader ist kostenlos im CODESYS Store erhältlich.

Zusätzliche Anforderungen

Technische Anforderungen
* Ethernet Adapter (bei Control RTE mit Intel oder Realtek Chipsatz)

Rechtliche Anforderungen
Jedes Gerät, das als PROFINET Controller oder Device an einen Endanwender vertrieben wird, muß durch ein PI Prüflabor zertifiziert werden.
Details zur Zertifizierung finden sie hier:
www.profibus.com/products/product-certification/

Einschränkungen

Zertifizierung aktuell nur möglich für
* Control RTE > V3.5.18.30
* Linux basierte Runtimes > V3.5.17.30

Lizenzierung

Einzelgerätelizenz: Die Lizenz kann auf der Steuerung, auf dem das CODESYS Laufzeitsystem installiert ist, verwendet werden.

Die Lizenzaktivierung erfolgt auf einem softwarebasierten Lizenz-Container (Soft-Container), der fest an die Steuerung gebunden ist. Alternativ kann die Lizenz auf einem CODESYS Key (USB-Dongle) hinterlegt werden. Durch Umstecken des CODESYS Keys kann die Lizenz auf einer anderen Steuerung genutzt werden.

Erforderliches Zubehör

Optional: CODESYS Key

Support

No Support

Technischer Support ist bei diesem Produkt nicht enthalten. Um technischen Support zu erhalten, erwerben Sie bitte ein CODESYS Support Ticket.

 

Für allgemeine Fehlermeldungen oder Vertriebs-Anfragen vor dem Kauf verwenden Sie bitte direkt das Kontaktformular "Meine Frage", das auch ohne Login genutzt werden kann. Eine Liste mit alternativen Support-Ressourcen finden Sie im Support-Bereich der CODESYS Group-Webseite.

Lieferant

CODESYS GmbH

A member of the CODESYS Group

Memminger Straße 151
D-87439 Kempten
Germany

Zusätzliche Downloads

Versionen

Version History

This is a license only product, for runtimes with a corresponding preinstalled library. No version information available.